Ocean-optics HR4000CG-UV-NIR Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Ocean-optics HR4000CG-UV-NIR. Ocean Optics HR4000CG-UV-NIR User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HR4000 and HR4000CG-UV-NIR Series
High-Resolution Fiber Optic Spectrometers
HR4000 / HR4000CG-UV-NIR
Installation and Operation Manual
Document Number 210-00000-000-02-0908
Offices: Ocean Optics, Inc. World Headquarters
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
E-mail: [email protected] (General sales inquiries)
[email protected] (Questions about orders)
[email protected] (Technical support)
Zobrazit stránku 0
1 2 3 4 5 6 ... 37 38

Shrnutí obsahu

Strany 1 - HR4000 / HR4000CG-UV-NIR

HR4000 and HR4000CG-UV-NIR Series High-Resolution Fiber Optic Spectrometers HR4000 / HR4000CG-UV-NIR Installation and Operation Manual Document

Strany 2

1: Introduction System Requirements You can use the HR4000’s USB connectivity with any computer that meets the requirements for the spectrometer ope

Strany 3 - Table of Contents

1: Introduction 6. The spectrometer passes the sample information to OOI software. 7. OOI software compares the sample to the reference measuremen

Strany 4

1: Introduction Note The HR4000 Breakout Box is compatible with HR4000 Spectrometers with Revision B or greater. HR4000 Spectrometers with serial nu

Strany 5 - 210-00000-000-02-0908 iii

1: Introduction Other Accessories Available Visit us at www.OceanOptics.com for a complete list of products available for all of your spectroscopy n

Strany 6 - About This Manual

1: Introduction 6 210-00000-000-02-0908

Strany 7 - Service

Chapter 2 Installing the HR4000 Overview You must install the operating software application prior to connecting the HR4000 Spectrometer to the com

Strany 8

2: Installing the HR4000 Serial Port Mode To use the serial port capacity of the HR4000 Spectrometer, the PC must be running a 32-bit version of the

Strany 9 - Introduction

2: Installing the HR4000 External Triggering Options You can trigger the HR4000 using a variety of External Triggering options through the 30-pin Ac

Strany 10 - System Requirements

Chapter 3 Troubleshooting Overview The following sections contain information on troubleshooting issues you may encounter when using the HR4000 Spect

Strany 11 - Interface Options

3: Troubleshooting 2. Locate the Other Devices option and expand the Other Devices selection by clicking on the "+" sign to the immediate

Strany 12 - Shipment Components

Additional Offices: Ocean Optics Asia 666 Gubei Road, Kirin Tower, Suite 601B, Changning District, Shanghai, PRC. 200336 Phone 86.21.5206.8686

Strany 13 - Other Accessories Available

3: Troubleshooting Linux Operating Systems For Linux operating systems, all you need to do is install the SpectraSuite software, then unplug and rep

Strany 14 - 6 210-00000-000-02-0908

Appendix A Calibrating the Wavelength of the HR4000 Overview This appendix describes how to calibrate the wavelength of your spectrometer. Though e

Strany 15 - Installing the HR4000

A: Calibrating the Wavelength of the HR4000 Calibrating the Spectrometer Preparing for Calibration To recalibrate the wavelength of your spectromet

Strany 16 - Configuring the HR4000

A: Calibrating the Wavelength of the HR4000 True Wavelength (nm) Pixel # Pixel # 2Pixel # 3Predicted Wavelength Difference Dependen

Strany 17 - External Triggering Options

A: Calibrating the Wavelength of the HR4000 7. Record the Intercept, as well as the First, Second, and Third Coefficients. Additionally, look at th

Strany 18 - Troubleshooting

A: Calibrating the Wavelength of the HR4000 Saving the New Calibration Coefficients: Serial Mode If you are connecting the HR4000 Spectrometer to th

Strany 19 - Mac Operating Systems

A: Calibrating the Wavelength of the HR4000 18 210-00000-000-02-0908

Strany 20 - Linux Operating Systems

Appendix B Specifications Overview This appendix contains information on spectrometer operation, specifications, and system compatibility. It also in

Strany 21 - About Wavelength Calibration

B: HR4000 Specifications HR4000 Components Table Ocean Optics permanently secures all components in the HR4000 at the time of manufacture. Only Ocea

Strany 22 - Calibrating the Spectrometer

B: HR4000 Specifications HR4000 Specifications The following sections provide specification information for the CCD detector in the HR4000, as well

Strany 23

Table of Contents About This Manual ... iv Do

Strany 24 - Procedure

B: HR4000 Specifications 210-00000-000-02-0908 Specification Value Entrance aperture 5, 10, 25, 50, 100 or 200 µm wide slits Order-sorting filter

Strany 25

B: HR4000 Specifications Any 32-bit version of Windows (when connecting the HR4000 to a PC via serial port) Compatibility for Handheld PCs To use t

Strany 26 - 18 210-00000-000-02-0908

B: HR4000 Specifications 30-Pin Accessory Connector – Pin Definitions and Descriptions The following table contains information regarding the functi

Strany 27 - Specifications

B: HR4000 Specifications Pin # Function Input/Output Description 16 GPIO (4) Input /Output General purpose software-programmable, digital input/ou

Strany 28 - HR4000 Components Table

B: HR4000 Specifications • The mating connector is Part Number P50–030S–TGF. • Mating the two components requires two 1.27 mm (50 mil) flat ribbon

Strany 29 - HR4000 Specifications

Appendix C HR4000CG-UV-NIR Spectrometer The HR4000CG-UV-NIR Composite Grating Spectrometer has a new proprietary grating and order-sorting filter to

Strany 30 - System Compatibility

C: HR4000-UV-NIR Spectrometer 210-00000-000-02-0908 Specification Value Gratings HC-1, 300 lines per nm grating Entrance aperture 5 µm-wide slit

Strany 31 - 30-Pin Connector

Index 1 15-pin accessory cable pinouts, 26 3 30-pin accessory connector diagram, 23 part numbers, 25 pin definitions, 24 A accessories, 5, 8 Accessor

Strany 32 - Descriptions

Index L L2 Detector Collection Lens, 20 Lens, 20 M memory chip, 2 mirror, 20 O OOIBase32, 8 Options Interface, 3 P packing list, 4 passwords, 4 pow

Strany 33 - 210-00000-000-02-0908 25

Table of Contents Chapter 3: Troubleshooting ...10 Overview ...

Strany 34 - 26 210-00000-000-02-0908

Table of Contents Appendix C: HR4000CG-UV-NIR Spectrometer...27 HR4000CG-UV-NIR Features ...

Strany 35 - HR4000CG-UV-NIR Spectrometer

About This Manual Document Purpose and Intended Audience This document provides the user of HR4000 Series Spectrometers (both HR4000 and HR4000CG-U

Strany 36 - Specification Value

About This Manual • Detailed instructions for SpectraSuite Spectrometer Operating Software are located at: http://www.oceanoptics.com/technical/Spe

Strany 37 - 210-00000-000-02-0908 29

About This Manual vi 210-00000-000-02-0908

Strany 38 - 30 210-00000-000-02-0908

Chapter 1 Introduction Product Overview The HR4000 High-Resolution Miniature Fiber Optic Spectrometer provides optical resolution as good as 0.025

Komentáře k této Příručce