000-00000-000-02-A
Filter- and Cuvette-Holder with
Attenuator and TTL-Shutter
FHSA-TTL
Installation and Operation Manual
Document Number 000-10000-140-02-1209
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
Ocean Optics Mikropack
Maybachstraße 11, D73760, Ostfildern, Germa
ny
Phone
+49 (0)711 34 16 96-0
Fax
+49 (0)711 34 16 96-85
E-mail: [email protected] (General sales inquiries)
[email protected] (Mikropack sales inquiries)
[email protected] (Questions about orders)
[email protected] (Technical support)
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - Attenuator and TTL-Shutter

000-00000-000-02-AFilter- and Cuvette-Holder with Attenuator and TTL-ShutterFHSA-TTLInstallation and Operation ManualDocument Number 000-10000-140-02-

Strany 2 -

1: Setup4 000-10000-140-02-1209Converting from Filter Holder to Cuvette HolderThe FHSA-TTL device can be used as either a filter holder or a cuvette h

Strany 3 - Table of Contents

1: Setup000-10000-140-02-1209 53. Unscrew the SMA Collimating assembly (74-UV, 74-UV-mount, filter thumbwheel, and filterholder) for the filterholder

Strany 4

1: Setup6 000-10000-140-02-12096. Dismount the filterholder by removing the screws.7. Replace the filter holder with the cuvette holder.8. Attach the

Strany 5

1: Setup000-10000-140-02-1209 7Inserting a Cuvette into the Cuvette HolderCuvette Holder – Top View► Procedure1. Insert the cuvette into the cuvette h

Strany 6 - About This Manual

1: Setup8 000-10000-140-02-1209

Strany 7

000-10000-140-02-1209 9Chapter 2FHSA-TTL SpecificationsThis section provides information on the environmental and physical specifications of the FHSA-

Strany 8 - Contents

2: FHSA-TTL Specifications10 000-10000-140-02-1209Specifications Specifications CriteriaSpectral Range UV-VISShutter Input TTL maximum 5 HzPower Requi

Strany 9 - Adjusting Optical Power

000-10000-140-02-1209 11IndexCconversion, 4cuvetteinsert, 7cuvette holderconvert, 4insert cuvette, 7Ddocumentaudience, iiipurpose, iiisummary, iiiFfil

Strany 10 - Procedure

Index12 000-10000-140-02-1209

Strany 11 - 000-10000-140-02-1209 5

Copyright © 2009 Ocean Optics, Inc.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system

Strany 12

000-10000-140-02-1209 iTable of ContentsAbout This Manual ...

Strany 13

Table of Contentsii 000-10000-140-02-1209

Strany 14 - 8 000-10000-140-02-1209

000-10000-140-02-1209 iiiAbout This ManualDocument Purpose and Intended AudienceThis document provides you with an installation section to get your sy

Strany 15

About This Manualiv 000-10000-140-02-1209

Strany 16 - Pinout Information

000-10000-140-02-1209 1Chapter 1SetupOverviewThe following sections provide instructions on unpacking, setting up and adjusting your Filter- and Cuvet

Strany 17 - 000-10000-140-02-1209 11

1: Setup2 000-10000-140-02-1209ContentsYour package should contain the following: FHSA-TTL device One IC-DB15-2 interface cable for shutter operatio

Strany 18

1: Setup000-10000-140-02-1209 3Shutter Switch PositionsSwitch Position ActionOPEN Shutter openCLOSE Shutter closedTTL Operation by external TTL signal